![Victron Orion-TR DC-DC Converter - 48 VDC to 12 VDC - 30AMP Isolated [ORI481240110]](http://elcapitan.com/cdn/shop/files/82878XL_{width}x.jpg?v=1684469008) 
              Victron Orion-TR DC-DC Converter - 48 VDC to 12 VDC - 30AMP Isolated [ORI481240110]
ELC-82878Orion-TR 48/12-30A (360W) Isolated DC-DC Converter
Isolated Model - separate in and out (-) leads
Remote On/Off Terminal
The remote on/off terminal eliminates the need for a high current switch in the input wiring. The remote on/off can be operated with a low power switch or for example the engine run/stop switch.
All Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current
An unlimited number of units can be connected in parallel.
High Temperature Protected
The output current will reduce at high ambient temperatures.
IP43 Protection
When installed with the screw terminals oriented downward.
Screw Terminals
No special tools are needed for installation.
Input Fuse (not replaceable)
On 12 V and 24 V input models only.
Adjustable Output Voltage
Not intended for battery charging (consider using an Orion-Tr Smart for battery charging).
Specifications:
- Input Voltage Range: 40-70 V
- Under Voltage Shut Down: 28 V
- Under Voltage Restart: 30 V
- Nominal Output Voltage: 12.2 V
- Output Voltage Adjust Range: 10-15 V
- Output Voltage Tolerance: +/- 0,2 V
- Output Noise: 2 mV rms
- Cont. Output Current at Nominal Output Voltage and 40 Degrees C: 30 A
- Maximum Output Current (10 S) at Nominal Output Voltage: 40 A
- Short Circuit Output Current: 60 A
- Cont. Output Power at 25 Degrees C: 430 W
- Cont. Output Power at 40 Degrees C: 360 W
- Efficiency: 87 %
- No Load Input Current (2): < 80 mA
- Galvanic Isolation: 200 VDC between input, output, and case
- Operating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)
- Humidity: Max. 95 % non-condensing
- DC Connection: Screw terminals
- Maximum Cable Cross-Section: 16 mm² AWG6
- Weight: 1.6 kg (3.5 lb)
- Dimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)
- Safety Standards: EN 60950
- Immunity Standards: EN 61000-6-3, EN 61000-6-1, EN 55014-2
- Automotive Directive Standards: ECE R10-5
 WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)
 
              ![Blue Sea 8247 AC Digital Multimeter with Alarm [8247]](http://elcapitan.com/cdn/shop/files/20757XL_{width}x.jpg?v=1683349926) 
            ![Blue Sea 5121 400AMP Class T Fuse [5121]](http://elcapitan.com/cdn/shop/files/19028XL_{width}x.jpg?v=1683347424) 
            ![Blue Sea Dual USB Charger Socket - 2 USB Ports w/Watertight Cap [1016]](http://elcapitan.com/cdn/shop/files/44767XL_{width}x.jpg?v=1683363154) 
            ![Blue Sea 1838 M2 AC Multimeter [1838]](http://elcapitan.com/cdn/shop/files/54771XL_{width}x.jpg?v=1683373829) 
            ![Blue Sea 7610 120 Amp SI-Series Automatic Charging Relay [7610]](http://elcapitan.com/cdn/shop/files/30594XL_{width}x.jpg?v=1683353488)